Generac Generator Fuel Consumption by Size

By Generator for House

A Generac Guardian standby uses about 1.2 to 1.5 gallons of propane per hour at half load in the 14kW size and 3.63 gallons per hour at full load in the 26kW size. On natural gas the 26kW draws 333 cubic feet per hour at full load. Most Generac generator fuel consumption questions are answered somewhere between those two units. The part people get wrong is assuming the size label does all the work. A 26kW loafing at half load burns less propane in an hour than a 20kW running flat out.

The figures here are the ones we use across our Generac reviews, rounded where model years differ. The manual for your exact model number is the final word, so check it before you size a tank or a gas line from this page.

Generac generator fuel consumption, size by size

Generac states fuel use in two units: cubic feet per hour for natural gas and gallons per hour for propane, each at full load and half load. This is how the four sizes homeowners ask about most look side by side.

SizeNatural gas, full loadPropane, full loadPropane, half load
14kWabout 180 to 210 ft³/hr (est.)about 2 to 2.3 gal/hr (est.)1.2 to 1.5 gal/hr
20kWroughly 200 to 250 ft³/hrabout 2.5 to 3 gal/hr1.3 to 2 gal/hr
24kW310 to 330 ft³/hrclose to 3.5 gal/hrabout 2 gal/hr (est.)
26kW333 ft³/hr3.63 gal/hr2.06 gal/hr

Cells marked est. are our estimate, scaled from the published figures on the larger sizes. Treat them as placeholders until you have the spec sheet for the model you are buying. For the 18kW and 22kW, the Generac generator fuel consumption figures fall between those rows. The 22kW runs about 1.5 to 2 gallons per hour at half load on propane, which puts it nearer the 20kW than the 24kW.

Half the watts costs more than half the fuel

The 26kW is the only size for which we have both load points published, and the gap between them is smaller than most people expect. At half load it draws 188 cubic feet of natural gas per hour against 333 at full load, and 2.06 gallons of propane against 3.63. Both work out to about 57 percent. Cut the electrical load in half and you save 43 cents of every fuel dollar, not 50.

Per kilowatt-hour the engine is slightly more efficient near its rating: 0.14 gallons per kWh at full load against 0.16 at half load. So a unit running flat out makes the cheapest electricity, hour for hour, and also empties the tank the fastest.

That matters for sizing, though less than you would think. A 26kW idling along at half load and a 14kW pushed near its limit burn close to the same propane per hour. That line in the Generac generator fuel consumption table is a good argument for ignoring fuel when you size. The stronger reasons to buy the right size are the purchase price and the gas connection, which our guide to what size generator for a 2,800 sq ft house goes through step by step. If you have not added up your loads yet, the generator size calculator does the arithmetic.

Outage run time, worked in gallons

Propane tanks are filled to 80 percent, so a 500-gallon tank gives you about 400 usable gallons. Divide that by the burn rate and you have the run time.

Unit and loadGallons per hourRun time on 400 usable gallons
26kW, full load3.63about 110 hours, or 4.5 days
26kW, half load2.06about 194 hours, or 8 days
24kW, full loadclose to 3.5about 114 hours, just under 5 days

A 250-gallon tank, at 200 usable gallons, roughly halves those numbers. At full load that is two days and a bit for either of the big units, which is why we tell 24kW and 26kW buyers on propane to start at 500 gallons, and to go to 1,000 if their outages last a week. A propane tank level monitor saves you a walk to the gauge once a day. Cold weather adds a limit that gallons do not show: a tank has to boil off enough vapor to feed the engine, and a small tank in freezing weather may not keep up with a 24kW or 26kW at full load. The propane tank sizing guide covers that side.

That is the tank half of Generac generator fuel consumption. The meter is the other half. A 26kW at full load pulls 333 cubic feet an hour, a bit over 3 therms. At the $1 to $2 per therm range used in our guide to the cost to run a whole house generator, that is $3.30 to $6.60 an hour, and about $1.90 to $3.80 at half load. Propane at $2 to $3.50 a gallon costs roughly twice as much per hour on the same unit. The catch is capacity. Many older residential meters cannot pass 300-plus cubic feet an hour alongside a furnace and a water heater, and a meter upgrade runs around $1,000 to $2,500. Our Generac 24kW review goes into that in more detail, because the 24kW hits the same wall.

Why your number will differ

Generac generator fuel consumption on paper and at your house will not match exactly.

Fuel type changes the output. On propane a Guardian makes its full rated power. On natural gas it gives up 10 to 15 percent, so the same engine does slightly less work for a similar draw.

Your house is not a load curve. A fridge, a well pump and a furnace rarely run at the same moment, and an air conditioner starting up briefly spikes the load. Real households average somewhere between the half-load and full-load rows.

Model years drift. Generac revises these units, and the same kilowatt label can carry a different burn rate across generations. That is why several cells above are ranges rather than single numbers.

A marginal gas line caps everything. If the pipe or the meter cannot deliver enough volume, the engine never reaches full output and the spec-sheet figure stops applying.

Putting fuel next to price when you compare brands

Generac generator fuel consumption is not the reason to pick one brand over another, but it belongs in the comparison rather than after the purchase. If a Champion or a Kohler is on your short list, run the same per-hour math for each before you look at prices. Our guide to Champion whole house generators and the Kohler dealer near you page list the current lineups.

Among Generac sizes, the purchase price differs far more than the fuel use does, so the installed quote is where the money is. Our where to buy a generator guide covers that side of the purchase.

FAQ

How much propane does a Generac generator use per hour? Roughly 1.2 to 1.5 gallons at half load on a 14kW, 1.3 to 2 gallons at half load on a 20kW, and 3.63 gallons at full load on a 26kW. The 24kW is just behind the 26kW at close to 3.5 gallons at full load.

What is Generac generator fuel consumption on natural gas? From about 180 cubic feet per hour at full load on a 14kW to 333 on a 26kW, or roughly 1.8 to 3.3 therms an hour.

Is it cheaper to run a Generac on natural gas or propane? Natural gas, usually by about half on the price ranges above. A 26kW costs roughly $3.30 to $6.60 an hour on natural gas at full load against about $7.30 to $12.70 on propane. Propane still makes full rated power and works where there is no gas main.

How long will a 500-gallon tank run a Generac? You get about 400 usable gallons. That is roughly 4.5 days at full load or 8 days at half load on a 26kW, and 11 to 14 days at half load on a 14kW.

Does a bigger Generac use more fuel? Only if you load it the same way. At half load a 26kW burns 2.06 gallons an hour, less than a 20kW at full load. Size the unit for the house and let the load set the burn rate.

What to do with Generac generator fuel consumption numbers

Use these figures to size the tank and to check the gas meter before the installer finds the problem for you. Generac generator fuel consumption runs from about 1.2 gallons an hour to 3.63 on propane, and from roughly 180 to 333 cubic feet on natural gas. Where you land depends more on what the house is drawing during an outage than on the badge on the side of the unit.