What can a 5500 watt generator run? In a typical outage: your refrigerator, a chest freezer, a gas furnace fan, a sump pump, all your lighting and internet, and one heavy kitchen appliance at a time. That covers the loads that actually protect a house through a storm. What it will not cover is the high-draw electric tier - central air conditioning, an electric water heater, an electric dryer, or an electric range - and understanding where that line sits is the whole game with this class of machine.
This class of machine is the classic mid-size portable: a gas engine on wheels, two 120V outlets, usually a 120/240V twist-lock, and enough muscle to carry a house's essential circuits through a multi-day outage. Popular 5500 watt portable models sit in the $600 to $1,000 range, which is a fraction of what an installed standby unit costs. The trade is capacity and convenience, and both come down to arithmetic.
Running watts, starting watts, and the 80 percent line
Every rating on a portable generator belongs to one of two buckets, and mixing them up is how people end up with a tripped breaker at 2 a.m.
Running watts (5,500 on this class) is what the machine sustains continuously. Starting watts - usually advertised around 6,800 to 7,000 on 5500-class units - is the brief surge reserve that motors borrow when they kick on. A refrigerator compressor, a furnace blower, and a sump pump each need roughly two to three times their running draw for the split second they start. The generator can absorb one motor starting at a time; it cannot absorb four at once.
Practical planning rule: keep the steady load at or under about 80 percent of running watts, so roughly 4,400 watts. The remaining margin absorbs the small surges and the sags a small engine naturally has when a load lands on it. Running any gas generator flat-out at its nameplate number for hours is hard on the engine and leaves you no room for surprises.
What a 5500 watt generator runs: the appliance list
Numbers below are the commonly cited draw ranges for standard US appliances. Your nameplates are the truth; treat these as planning figures.
The essential tier, all at once (about 1,000 to 2,200 running watts):
- Refrigerator: 100 to 200 watts running, a surge of 600 to 1,200 at compressor startup
- Chest freezer: similar, often slightly lower
- Gas furnace blower, half-horsepower: 500 to 600 watts running, roughly 1,500 starting
- Sump pump, half-horsepower: 800 to 1,050 watts running, 2,000 to 3,000 starting
- LED lighting, a whole house of it: 50 to 150 watts
- Router, modem, phones, laptop charging: 50 to 100 watts
- Television: 100 to 150 watts
That stack is what most people actually need during an outage, and a 5500 watt machine carries it with room to spare. The trick is sequencing: let the sump pump finish its start before the fridge compressor kicks, which in practice happens naturally because they cycle on their own timers.
The kitchen tier, one at a time (1,000 to 1,500 watts each):
- Microwave: 1,000 to 1,500 watts input
- Drip coffee maker: 800 to 1,000 watts
- Toaster or toaster oven: 1,200 to 1,500 watts
- Electric kettle: 1,500 watts
Any single one of these rides along on top of the essential tier. Two at once gets tight. A space heater at 1,500 watts behaves the same way - it fits, but it is a lone passenger, and in a real cold-weather outage the furnace blower usually does more with those watts than a space heater does. Our state-by-state outage reference is useful here for judging how long these loads need to hold in your region.
The loads that stay off limits
This is the honest part. Central air conditioning in a typical home needs 3,500 watts and up just to run, with a starting surge that can double that - a 3-ton condenser alone can demand more than this generator's entire surge rating. An electric water heater draws 4,000 to 4,500 watts. An electric dryer wants 3,000 to 5,000. An electric range pulls 2,000-plus per large burner, more with the oven. A large well pump (three-quarter horsepower and up) can spike past 4,000 watts at startup.
None of these run on a machine this size, and no accessory changes that. If your heat, hot water, and cooking are all electric, this class of machine keeps your food cold and your basement dry but cannot keep your house warm. That is a house problem more than a generator problem, and it is worth knowing before an outage rather than during one.
A sample outage plan that stays under the line
One workable steady-state stack: refrigerator (150) + chest freezer (150) + furnace blower (600) + sump pump when it cycles (1,000) + lighting (100) + internet and charging (100) + television (130). Total: about 2,230 running watts, comfortably under the 4,400 planning line. Surge events stay under control because the motors start at different moments.
On top of that baseline, run one 1,500-watt convenience load - the microwave at dinner, the coffee maker in the morning, the kettle for tea. Kick the convenience load off before starting anything with a motor, and the math never gets close to the ceiling.
If your list looks different - a medical device, a well pump, a window AC unit - plug every nameplate into our generator size calculator instead of guessing. Ten minutes with the actual numbers beats any rule of thumb.
Enough machine, or the wrong machine?
A 5500 watt portable is the right answer when the mission is essentials: food, heat via a gas furnace, water via a sump pump, light, and communication. It is the wrong answer when the mission is "the house keeps working like nothing happened." That second mission belongs to a 14 to 26 kW standby unit with an automatic transfer switch, installed and wired into the panel.
The middle path some households take is a manual transfer switch for the portable's dedicated circuits - it eliminates the daisy chain of extension cords and makes the generator safe to bond into the house wiring. Our walkthrough on where to buy a generator covers which retailers stock both the machine and the switch kit, and the Champion whole house generator guide shows what the step up to a standby unit actually buys you. For sizing the full-house version, start from what size generator a 2,800 sq ft house needs rather than scaling this article's numbers.
FAQ
Will a 5500 watt generator run a refrigerator and a freezer at the same time?
Yes, easily. Both together draw 200 to 400 running watts; their startup surges overlap only if the compressors happen to start in the same instant, which is rare and still within the surge rating.
Can it run a well pump?
A half-horsepower pump, usually yes - about 1,000 running watts with a 2,000 to 3,000 watt start. Three-quarter horsepower and larger pumps can demand more at startup than this class supplies, so check the pump's locked-rotor amps before counting on it.
Can it run a window air conditioner?
A small 5,000 to 6,000 BTU window unit (400 to 700 running watts, with a manageable surge) generally works. Large window units and any central system do not.
How long does it run on a tank of gas?
At half load, most models in this class run 10 to 12 hours on their onboard tank. Real-world runtime depends on your steady load and on altitude, so treat the spec sheet's number as a best case.
The short version: what a 5500 watt generator runs is every essential circuit in the house, run in the right order, one heavy convenience load at a time - and nothing from the all-electric heavy tier. Size your loads before the storm, and this machine earns its floor space.